Textile curtain composed of a woven slat made of multi-layered thread with intumescent fabric and insulation by silicate plate, winding with gravity or tubular motor.
Surface-mounted/tunnel installation, control box with battery for fire detection.
The fire-rated metal curtain is an essential solution for fire safety indoors. It provides reliable protection that complies with current standards in case of fire.
Certification:
- Tested according to standards: EN 1634-1 and EN 1634-3
- Classified according to standard: EN 13501-2
- Cycle test: Validated according to standard C2 (> 10,000 cycles)
- CE marking: Compliant with standards EN 13241 and EN 16034 PV DAS
Installation is possible on or in the wall or opening, with approved mounting surfaces such as aerated concrete, silico-calcareous brick, concrete, and masonry.
Motorization: 230 V tubular motor with gravity descent and control box
Safety device: Optical and acoustic signaling
Construction: Galvanized steel side guides and cover box
Options:
- Smoke version: Based on Sa or S200
- Backup battery: To maintain the open position in case of power failure
- Coating: Galvanized steel parts coated with powder coating in the RAL color of your choice
- Smoke detector: For an autonomous system
- Various switches
Contact us for more information or for a custom configuration tailored to your specific needs.
Flexible fire-resistant and fireproof door EI60-EI120
Questions & Answers
What is the purpose of a fire-resistant textile curtain?
A textile fire curtain is a protective barrier that isolates one compartment from another, preventing the spread of flames, smoke and heat.
What is CE marking?
CE marking guarantees the user or customer that the product complies with safety and quality standards. Marking is compulsory before a product can be placed on the market.
What are the abbreviations E, EW and EI?
Products bearing the EEW and EI labels in accordance with European standards are valid. E (tightness) EW (flame-tightness) and EI (heat-tightness /below 140°)
What dimensions are permitted?
The maximum authorised dimensions are notified in the PVs approved by the test laboratories.